Suoer SW-6000 Corneal Topograph

$5,980.00
Add to Cart
Description
Measuring method: Placido cone
Coverage:10.91mm(Diameter)
Measuring range for curvature radius: 5.5mm-10.0mm
Diopter range: 33.75D-61.36D
Precision: ±0.02mm
Placido rings: 31 rings
Measurement points: 7,936 points
Display axial curvature map, tangential curvature map, elevation map, imitated keratoscope map and 3D cornea map
Image output: High-quality color inkjet printer
Adjust range: left/right 86mm ; forward/backward 40mm ; up/down 30mm ; chinrest 5omm
Cornea contact lenses fitting function
Keratoconus detecting fu

Suoer SW-5000 Tonometer

$4,860.00
Add to Cart
Description
Measuring Range:1mmHg~~60mmHg
Measuring Range Setting:30mmHg, 60mmHg
Measuring Accuracy:1mmHg;
Measuring Distance:11mm
Focus Method: focus points +focus indication
Focus Mode: dimensional auto-focus/manual focus/touch screen semi focus
Eye Fixation:Green LED
Stroke of Moving section: X:80mm
Y :40mm
Z:20mm
Display: large color liquid-crystal screen
Output: thermal printer
Features:
1.Integrated ORA(Ocular Response Analyzer)
2.Unique waveform based on three weighted average value and indicate the low reliable readings
3.Touch screen focus
4. Non contact measurement, avoid cross infection
5. built-in 24 hours IOP trend analysis

Suoer SW-3200L Portable Ultrasound

$3,050.00
Add to Cart
Description
Frequency: 50MHz
Scaning Mode: Wide range linear scanning mode, undistorted, Sulcus-to-Sulcus.
Scanning Range: 16mm*9mm; 10mm*6.5mm
Image Resolution(full screen):50um
Scaning Lines: 1024 lines, 15 um between each,high density & high resolution
Geometry Distortion: Both Vertical & Lateral rate<3%,no compensation, undistorted image
Probe: Multi-Dimension, precise locating articulated arm
Display Mode :UBM? UBM+A.
Magnify: Special independent ultrasound magnify system,better image in Anterior Segment.
Eye Fixation: Unique Eye position and LED system
Working Platform: Windows XP?VISTA?WINDOWS7
Image Process: Length, angle measurements
Output: Windows brow

Suoer SW-2000 Portable ultrasound system

$2,460.00
Add to Cart
B scan
Frequency: 10MHz/20MHz (optional) ,Magnetic driven, noiseless
Scanning Mode: Sector Scanning
Magnify:Multi continuous magnification,Real-Time magnification
Resolution: Lateral =0.3mm;Vertical=0.2mm
Geometry position precision: Lateral =10%;Vertical=5%
Depth:60mm
Enhance the part of vitreous body and retina
Gain of probe:30dB-105dB
Scanning Angle:53°
Gray Scale: 256
False Color: Multi colors. OCT
measurement type: multigroup distances, perimeters and areas
Image postprocessing: multiple curves processing, Pseudo-color processing curve
Movies: 100 images movie review, AVI JPG format image output
A scan:
Frequency:10MHz, with LED
Depth: 40mm
Precision:±0.05 mm
Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
Eye mode: Phakic / Aphakic / Dense / Various IOL
IOL Formula: SRK-II, SRK-T, HOFFER-Q, HOLLADAY,BINKHORST-II, HAIGIS
Stat. Calculation: Average and standard deviation
S

Suoer SW-1000 Tonometer

$1,850.00
Add to Cart
Description
A scan probe: 10MHz import small size probe, built-in luminotron
Measuring range: 15mm-40mm
Measurement precision: ±0. 05mm; with macula lutea trace function
Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
Method of measurement: immersion and contact
Eye mode: Phakic/ Aphakic/Dense/ various IOL
IOL formula:SRK-II?SRK-T?BINKHORST- ??HOLLADAY?HOFFER-Q?
HAIGIS
Enter the name & ID; easy to check archive
Storage: 10 cases, 5 readings each case
Output: A scan waveform and IOL calculation sheet

P scan probe: 20MHZ, angle of 45 degrees makes easier operation
Resolution: 5um
Measuring range: 150um~1500um
Display: SINGLE mode and MAP mode
Can display ultrasound waveform when measuring
Each group is the average of 20 measurements
Switch between IOP measured value and actual value
Can input name, ID and operator’s name